ZVA II AUTO NOZZLE UNLEADED 55L/MIN, N

ZVA II AUTO NOZZLE UNLEADED 55L/MIN, NO4 GUARD, 3/4'' SWIVEL
ZVA Slimline 2 Nozzle for Unleaded Petrol As the most prevalent nozzle on petrol forecourts in Europe and the UK, the ZVA range is the toted as the best refuelling nozzles money...
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Hytek
What makes this SWIVEL the right choice?
ZVA Slimline 2 Nozzle for Unleaded Petrol
As the most prevalent nozzle on petrol forecourts in Europe and the UK, the ZVA range is the toted as the best refuelling nozzles money can buy. Part of the appeal is in the design, the modular component structure makes the nozzle easy to service and replace, increasing the life cycle of the nozzle and improving the economy.
The nozzle has a max flow rate of up to 55L/min and a 3-position stay open latch for easy fuelling - this can be disabled if necessary for better control over the refuelling operation. The nozzle will also shut off the fuel flow when the tank is full with less drain off, making ZVA the more environmentally friendly option.
The nozzle’s stainless-steel tipped spout protects against wear and tear for long life.
Product Features:
- ATEX certified.
- Automatic shut off valve to prevent overfill.
- Suitable with petrol, kerosene and ethanol to E85
- 1" BSPF swivel inlet
- Approved for resale.
- 3 position stay open latch which may be disabled if required
- For use with electric pumps only
- Max Pressure: 50psi (3.5 bar)
- Nozzle Spout OD: 21mm
- Max Flow Rate: 55lpm (litres per minute)
- 1 year warranty
Technical data
Full specifications
| Construction | |
| Outlet size | 3/4'' swivel |
| Reference | |
| SKU | ZVA.LF2 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.
Verified customers
What buyers say
Still not sure which tank you need?
Our specialists have advised thousands of Irish customers. Free advice, no obligation.