TIGERLOOP BIO

TIGERLOOP BIO
The Tigerloop de-aerator eliminates air locks from oil lines, preventing burner lockouts and improving heating system reliability.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Kingspan Energy
What makes this BIO the right choice?
TIGERLOOP BIO
The new and improved third generation automatic oil de-aerator.
The Tigerloop Bio pre-heats the oil to at least room temperature by absorbing the heat from the boiler room and friction heat from the oil pump.
The Tigerloop Bio is used in combination with a separate oil filter.
The benefits of Tigerloop are applicable anywhere you use a light oil burner. The Tigerloop Bio is designed to be compatible not only with standard mineral fuels like C2 Kerosene and class D gas oil but also bio-liquids and bio liquid/ mineral fuel blends up to B100
- Suitable for indoor installation.
- Eliminate the risk of leakage in the return line.
- Reduce the flow of fuel, preserve quality of oil.
- Less dirts/sludge transported in the system.
- Better combustion, reduces oil consumption.
- Solve the problem of nozzle dripping causing soot build up.
- Provides the best possible operating conditions for pump.
- Satisfied customers / reduces call backs.
- The installers save time and money (easier installation).
Specifications:
- Max. nozzle capacity: 90 LPH
- Max. return oil pumped into Tigerloop: 100 lph
- Max. oil flow: 190 lph
- Operating Temperature: -6 deg - 70 degF
- Max. Ambient Temperature: 70 degF
- Max. operating pressure in feed line: -.06 to +0.5 bar
- Connections: 1/4"-NPT (F)
- Fuel type: Nos. 1 & 2, B5 BioHeat Biofuel
Technical data
Full specifications
| Reference | |
| SKU | 0001409 |
| EDEL code | DELIVERY |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.