QUICKSTOP ADVANCE FLOAT VALVE

QUICKSTOP ADVANCE FLOAT VALVE
Precision float or inlet valve for automatic water level control in tanks and cisterns. Easy installation — no specialist tools required.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Kingspan Energy
What makes this VALVE the right choice?
QUICKSTOP ADVANCE FLOAT VALVE
The QuickStop Advance float valve is designed as an alternative to conventional ballcock valves in water tanks to protect booster pumps. The Quickstop Advance goes instantly from fully open to fully closed, preventing repeated stop/start cycling of pumps when filling tanks or cisterns. QuickStop plastic float valve has a very high flow rate allowing rapid filling with minimal pressure loss.
This is a fully adjustable water valve; the Locking lever (at the center hinge) easily sets the minimum and maximum tank liquid levels and the length of the float arm can be simply adjusted too giving you great flexibility from 0 to 180o. The adjustable arm has 6 different settings enabling you to lengthen the arm up to 60mm. This Quickstop Advance float valve be used in water tanks, toilet cisterns, roof tanks, header tanks instead of a ballcock and float valve. When water is drawn from the tank, the QuickStop has a delayed re-start level of approximately 3cm, which further reduces the stop/start frequency of the pump. QuickStop float valves are hydraulic water level regulators with a hydraulically operated closure.
Available in to suit 3/4' or 1' pipework.
Specification:
- Operating Pressure: 0.2 to 6 bar
- Max Pressure: 10 bar
- Bursting Pressure: >20 bar
- Operation: Continuous
- Operating Temperature: 0 to 50oC
- Float Movement Range: 0 to 180o
- Float Arm Adjustment: upto 60mm (6 settings)
- CE Mark
Technical data
Full specifications
| Reference | |
| SKU | QS075 |
| EDEL code | DELIVERY |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.
Verified customers
What buyers say
Still not sure which tank you need?
Our specialists have advised thousands of Irish customers. Free advice, no obligation.