HYTEK PROFESSIONAL AUTOMATIC DIESEL NO

Hytek Professional Automatic Diesel Nozzle
Precision dispensing nozzle for controlled fluid delivery. Automatic shut-off prevents overfilling and spills.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Hytek GB Ltd
What makes this Nozzle the right choice?
Hytek Professional Automatic Diesel Nozzle
The Hytek engineered professional automatic nozzle is manufactured to the highest industry standard, providing you with an affordable alternative to some major brands without having to sacrifice usability or environmental responsibility.
The professional automatic diesel nozzle is a fully certified ATEX product, it meets the highest standard of operation. The nozzle comes complete with an automatic shut off valve that prevents the over filling and spilling of diesel when the vehicle is full. As standard, there is a 3 position stay open latch, ideal for easy fuelling which can be removed as per your operational needs.
Product Features:
- For use with Diesel/ Biodiesel up to B30
- Suitable for most standard filling speeds
- Overfill Prevention
- Flow Rate: 10-80lpm (Litre per minute)
- 1" F BSPP Swivel.
- 25mm Nozzle Spout (OD)
- Removable 3 position, stay open latch.
- Pumping systems only.
- ATEX Certified
- Stainless steel tipped spout
- Max pressure 58PSI/ 4 Bar
- 1 year warranty
Technical data
Full specifications
| Physical | |
| Empty weight | 1 kg |
| Reference | |
| SKU | NOZA.X |
| EDEL code | EDELP00183251 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.