PERMASTORE SLURRY TANK - 348M³ TO 50,0

Permastore Slurry Tank - 348m³ to 50,000 m³
? slurry storage tank built to Nitrates Action Programme requirements. Engineered for long-term outdoor installation on Irish farms.
Price on Application
This product requires a tailored quote. Complete the enquiry form and our team will be in touch.
Enquire About This Product
Submit the form below and our team will be in touch with pricing and availability.
Permastore
What makes this m³ the right choice?
Product Description
Permastore Slurry Tank - 348 m³ to 50,000 m³
PERMASTORE® Glass-Fused-to-Steel slurry tanks are the premium solution to effective and secure slurry storage. With a history of durability, performance and longevity, Permastore Slurry Tanks help to safeguard the environment, and prevent nitrates from agricultural sources polluting ground and surface water quality using good farming practices in the storage of slurry.
These glass lined steel tanks provide the strength and flexibility of structure from the steel while protecting the structures surface with the glass lining. When the glass is fused to steel it results in a very strong durable and resilient product. The materials when combined result in a product that exhibits unparalleled physical property characteristics that provide excellent resistance to both corrosion and wear.
Permastore and its preferred installer partners actively support grant applications under Ireland’s TAMs 3, through design declarations and any required drawings/plans.
To make an enquiry, please click on Permastore Slurry Tanks and fill out the contact form.
Benefits:
- Corrosion resistance of Glass-Fused-to-Steel reduces day-to-day operation and maintenance costs
- Exceptional lifetime value - a design life of 30 years and a proven life service being over 60 years
- Modular bolted construction enables simple logistics to remote locations and facilitates rapid and cost-effective site installation
- Above ground storage provides security against flooding and minimises the risk of accidents
- Tanks can be fitted with a range of covers to provide effective odour control and weather protection
- The availability of taller tanks simplifies mixing for maximum nutrient benefits
- The modular design allows for future extension, modification or relocation
Typical PERMASTORE® Slurry Storage System:
- Jetter - Easy to operate directional jetter to reduce slurry crusts.
- Platform and ladder - Handrails and trapdoor for safety. Removable ladder to prevent unauthorised access.
- Pump - For filling tank or loading field spreader. Adjustable for depth of pit. Directional jetter for mixing.
- PVC Dome Roof - Optional extra for Roof Ready tanks to provide odour control and weather protection.
- Valves - Large bore valves for in-line or in-pit fixing. Top access for maintenance. Lockable for safety.
- Mixer - Through-the-wall agitation for simple and efficient mixing.
- Base design - High specification for structural integrity
Capacities:
Permastore offer slurry tanks from 13m³ to 50,000m³ - example of sizes can be seen in the chart below

Pricing Examples:
Permastore and its preferred installer partners actively support grant applications under the UK’s Farming Transformation Fund – Slurry Infrastructure Grants & Ireland’s TAMs 3, through design declarations and any required drawings/plans.
Current cost example covering Generic/standard concrete base on a suitable stoned up level base by others. (No site specific base design or ground investigation included)
Single membrane tension cover with 2no. standard 1m x 1m viewing hatches (inclusive of crane hire, AP and MEWPS for high level access)
- For a 4,660m³ Tank capacity 106-20 = €333,652 + VAT
- For a 2,525m³ Tank capacity 78-20 = €200,640 + VAT
- For a 1,044m³ Tank capacity 50-20 = €116480 + VAT
As every site is different and some farmers want more involvement than others, no costs for travel, welfare, telehandler hire, deliveries/collections, site specific base designs, excavation and stoning up of the tank base and at least 3m around the outside of the tank to allow access for MEWPS to install the cover, installation of any of the ancillary equipment is included in these sample prices.
Technical data
Full specifications
| Reference | |
| SKU | PERM |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.