MAINS SINGLE CHANNEL TANK ALARM

MAINS SINGLE CHANNEL TANK ALARM
This is a simple and cost effective solution when the user only requires to be alerted of one scenario, therefore making the multi-zone tank level alarm over-specified.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Centre Tank Services Ltd
What makes this ALARM the right choice?
MAINS SINGLE CHANNEL TANK ALARM
The single channel fuel tank alarm system provides the user with the choice of setting the alarm to alert of either a high level, low level or bund leak depending upon their requirements. This is a simple and cost effective solution when the user only requires to be alerted of one scenario, therefore making the multi-zone tank level alarm over-specified.
Available in either mains or battery power, the single channel fuel tank alarm has a clear, descriptive seven segment LED display that informs the user of the activated tank state. Both versions feature a test button that will activate the 90dB sounder and flash the display showing the current configuration of the tank level alarm, and a mute button to silence the sounder. The battery powered version has a low battery warning to give notice that the battery needs changing.
The mains powered fuel tank alarm has the additional feature of a volt-free relay for connecting the fuel storage tank alarm to another piece of equipment on site such as a building management system, or another mains powered single channel alarm allowing the alarm status to monitored remotely for example in the office. Whilst commonly used as a diesel tank alarm, it is also suitable for use with a range of fluids such as water, waste oil and chemicals (see accessories for other tank level probes).
Using the single channel alarm as a remote warning device
- The mains powered versions of the single channel alarm come with a relay to allow you to connect it to a single relay on another alarm as a remote warning device
- The second alarm can be positioned 100m away from the other, inside the office for example, meaning that you don't have to be in sight/ear shot of the tank to be alerted to a problem
- The two alarms will act independently from one another meaning that if one of them is muted, the other will continue to sound until it is muted or the zone is unactivated
Features:
- Single zone mains powered tank alarm to warn of either a high level, low level or fluid in the bund
- Probe c/w 5m cable and 1.5" brass cap
- 90db sounder & descriptive red LED text display to clearly warn of the activated tank state
- Test & alarm mute functions
- Automatically reversed float logic for low zones so that it is ready for use again once the fluid level has increased
- Weatherproof IP55 enclosure with 4 external mounting lugs
- Mains, battery & mains with battery back up version available - please enquire
- Battery version has low battery warning for indication that it needs to be replaced
- Mains version c/w relay connecting to external equipment e.g. another alarm or BMS for remote monitoring
Technical data
Full specifications
| Reference | |
| SKU | SWS2002 |
| EDEL code | EDELP00182267 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.