MAINS MULTI-ZONE TANK ALARM

MAINS MULTI-ZONE TANK ALARM
Each zone can be configured in any of the three functions
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Centre Tank Services Ltd
What makes this ALARM the right choice?
MAINS MULTI-COMPARTMENT TANK ALARM
The Mains Operated Multi-Compartment Fuel Tank Alarm system has three functions; to detect and warn of a tank overfill, a high/low liquid level and a bund leak. If this fuel tank alarm identifies any of these issues, the zone in question will light up on the alarm's screen, combined with an alarm sounder and flashing orange strobe, which provides the user with a clear warning of the activated tank state. Each zone can be configured in any of the three functions High, Low or Bund, enabling the complete customisation of these fuel tank alarms based upon the user's requirements with a very simple set of electrical jumpers.
An option is available complete with three relays, to allow external equipment to be connected to each zone of the tank level alarm such as building management system for remote monitoring. This level and bund alarm also has the additional feature of controlling the pump from the relays (if fitted). When the fuel storage tank contents are 'low', the pump switches on and stays on until 'high' is reached.
If you require a tank level alarm for something other than diesel or light oil, we also supply a water and chemical alarm probe, and a high viscosity oil tank level probe - which is also suitable for AdBlue as well as high viscosity oils. Please see the accessories table for more information.
Please note: The probes required do not come as standard with the fuel tank alarm box. Please view the accessories to select the combination you need.
Specification:
- Mains multi-channel tank alarm for alerting of a combination or all of the following tank states: high, low and/or bund
- 85db sounder & flashing orange strobe to warn of a problem
- LED channel lights up to indicate the issue
- Flashing orange strobe
- Test & alarm mute functions
- Automatically reversed float logic for low zones
- Weatherproof IP55 enclosure with external mounting lugs
- Enclosure has rain drip guard above panel and around sounder
- Standard box with multiple input voltages 110/230v, 12v/24v DC
- Option with relays to connect to external equipment e.g. other alarms or building management systems for remote monitoring
- Version with relays can also be used to control the pump operation on a day tank
Technical data
Full specifications
| Reference | |
| SKU | SWS5000 |
| EDEL code | EDELP00182267 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.