CARBERY 1100L BUNDED GENERATOR OIL TAN

CARBERY 1100L BUNDED GENERATOR OIL TANK
Fuel is stored in the inner tank, whilst the outer tank acts as a failsafe in case of a spill, significantly reducing the risk of an environmental pollution incident.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Carbery Plastics Ltd
What makes this TANK the right choice?
CARBERY 1100L BUNDED GENERATOR OIL TANK
This Carbery 1100L Bunded Oil Generator Tank consists of a ‘tank within a tank’. Fuel is stored in the inner tank, whilst the outer tank acts as a failsafe in case of a spill, significantly reducing the risk of an environmental pollution incident. The 1150 Litre Bunded Oil Tank is a compact tank and is space efficient. Carbery Bunded tanks are HVO compatible.
Benefits:
- Low Maintenance UV stabilised for protection against the damaging effect of sunlight
- Manufactured from premium quality corrosion resistant material
- EN13341 Compliant
- OFCERT approved
- Manufactured to ISO Standards
- All Carbery Bunded Heating Oil Tanks are supplied complete with a conditional 10-year warranty against manufacturing, material and design defect.
Comes With:
- 2” lockable oil tank fill point
- Extended offset fill
- 5” lockable oil tank inspection point
- Lockable access lid
- 32mm electronic gauge point
- Tank Contents Dipstick
- 1” BSP bottom outlet
- Nominal Capacity: 1115 Litres
- Brim-full Capacity: 1174 Litres
Technical data
Full specifications
| Physical | |
| Capacity | 1115 L |
| L × W × H | 194 × 84 × 139 cm |
| L × W × H (mm) | 1940 × 840 × 1390 |
| Empty weight | 130 kg |
| Construction | |
| Material | MDPE |
| Reference | |
| SKU | BTGR1100R with offset fill |
| EDEL code | EDELP00002052 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.