BIODISC NA6 SEWAGE TREATMENT PLANT

BioDisc NA6 Sewage Treatment Plant
Packaged sewage treatment system providing secondary and tertiary treatment to EPA standards. For properties without access to mains drainage.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Klargester (Ac)
What makes this Plant the right choice?
BIODISC NA6 SEWAGE TREATMENT PLANT
The new and improved N Range BioDisc Sewage Treatment Plant is engineered to treat wastewater to a very high standard delivering peace of mind with reliable treatment of wastewater, offering affordable lifetime costs compared to other treatment processes.
For domestic dwellings without access to mains drainage, the BioDisc Sewage Treatment Plant provides a reliable, efficient and environmentally safe solution to your sewage disposal needs. It is ideal for locations where discharge is to sub-surface irrigation, or to a suitable watercourse where approved by the Regulator, and where a septic tank will not meet the required standards. For added peace of mind, we offer an extended warranty period of 7 years. Terms and conditions apply please visit Warranty Terms.
Assured Performance
BioDisc is a high performance package treatment plant which, in normal domestic situations, will produce effluent qualities of better than 8mg/l BOD, 13mg/l SS and 4mg/l ammonia.
Product Benefits:
- Improved BOD, SS & NH4N effluent levels
- New split cover, offering safer access for service
- Affordable lifetime running costs
- Odour free
- Silent Operation
- 7 year warranty *(T&C's apply)
- Third party tested to EN-12566-3
Specification:


Breakdown Process
- Primary settlement tank: Wastewater and sewage flows into the primary settlement tank where the large solids are retained for future removal.
- First stage biological treatment: The liquor and fine solids then flow into the Biological Treatment Zone 1 where the first stage of treatment occurs.
- Second stage biological treatment: The liquor is then fed forward at a controlled rate into Biological Treatment Zone 2 for further treatment.
- Final settlement tank: The clean liquid passes into the final settlement tank where it can be discharged to ground or water course.
Due to higher demands on wastewater effluent qualities, Klargester have designed a new tertiary module that works alongside our range of sewage treatment plants to achieve a higher BOD removal.
BioTreat Tertiary Treatment System
The Tertiary Treatment system comprises of horizontal modules constructed from GRP, filled with granular material which provides the hydraulic flow path and the environment to achieve improved effluent quality.
Benefits:
- Improved effluent quality – BOD5 99.2%*
- Improved Suspended Solids – 99.3%*
- Reduced risk of a pollution incident
- Third party tested to EN 12566-3
- Easy to install and maintain
- Affordable service plans available
*When the Tertiary Treatment System is used alongside our Klargester Commercial BioDisc.
Specification (BIOT08 model):-
- Daily Flow - 11.25 m3/d
- Diameter - 2605 mm
- Length - 7933 mm
- Inlet Invert - 600/1000 mm
- Outlet Invert - 700/1100 mm
- Inlet / Outlet Pipework - 160 mm diameter
To find out more about the Klargester BioDisc click on Klargester BioDisc
*DELIVERY TERMS
All tanks are delivered on 45ft Flat-bed Articulated Trailers, so off-loading equipment on site is necessary.
HIAB off-loading is available at extra cost, if requested.
It is the responsibility of the customer to inform us, if off-loading equipment is required.
WOULD YOU LIKE A SITE ASSESSMENT DONE?
Before you purchase your sewage treatment system you may need advice on which system is suitable. From percolation tests and site assessments to specifying the correct sewage treatment plant for installation we can help you through the process. If you would like our help, please click on Site Assessment Report and fill out the form and we can take it from there.
Kingspan offer a commissioning and maintenance service on all their wastewater products. Your service and maintenance visit will include; system integrity and operation, check of all moving parts, effluent quality, flow rates, discharge consents and management system checks. Kingspan are currently offering free commissioning valid within three months of purchase.
DO YOU REQUIRE COMMISSIONING?
To ensure your system operates to maximum efficiency, we recommend tried and tested commissioning by Klargesters own trained engineers.
Our unrivalled knowledge means that we are best placed to carry out bespoke assessments to get your system up and running. The commissioning will also provide you with a unique checklist against your system, ensuring your complete peace of mind and reassurance that your system's mechanical and electrical components are in good working order.
WHAT'S INCLUDED IN THE COMMISSIONING? CLICK HERE FOR MORE INFORMATION
For more information download the information below, call 0818 543 500 or go to Kingspan Service
Technical data
Full specifications
| Physical | |
| Diameter | 1995 mm |
| Empty weight | 310 kg |
| Reference | |
| SKU | NAUBGA107A100K |
| EDEL code | DELIVERY |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.
Technical documentation
Downloads & data sheets
Product video
See the Plant in action
Verified customers
What buyers say
Still not sure which tank you need?
Our specialists have advised thousands of Irish customers. Free advice, no obligation.