BIODISC BA-BB DRIVE ASSEMBLY (POST 2006 MODELS) KIT 3
Complete installation or conversion kit with all components required. Straightforward fitting — full instructions included.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Kingspan Parts
What makes this 3 the right choice?
BIODISC BA-BB DRIVE ASSEMBLY (POST 2006 MODELS) KIT 3
This is for the Post 2006 Models of the BA/BB Bio Disc. This is a full drive assemlbly replacement kit including the motor, capacitor, belt, both pulleys & locking element.
The BA-BB Bio Disc Drive Assembly Kit 3 includes :-
x1 Panasonic Motor-Gearbox - 0015500
x1 Short 1120mm Belt - 0012828
x1 Top Pulley - 0013725
x1 Bottom Pulley - 0600082
x1 Locking Element - 0013170
x1 3uf Capacitor - 0019920
TANK SERVICING
Why does my system need serviced?
- It’s important that your sewage treatment plant or septic tank system is emptied and maintained regularly to continue operating optimally.
- Poorly performing systems can cause serious health hazards as well as local pollution risks.
- Recent Building Regulations (Part H 2010 – BS EN 12566) state that regular emptying and maintenance of small sewage treatment plants must be undertaken by the homeowner at least once per year, or as per the manufacturer’s guidelines.
- As a homeowner, you must also ensure that your system remains in good order and replace it when necessary.
- We do recommend that you keep a detailed log of when your system is inspected, maintained, emptied or serviced as you may need these details in future.
- Our treatment plant service includes a full check to ensure everything is in perfect working order.
- Our team can be reached on helpingyou@kingspan.com or 033 240 6868
- Current lead time is 7-10 days for service visit
Technical data
Full specifications
| Reference | |
| SKU | 1009109 |
| EDEL code | DELIVERY |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.