ARMORGARD FLAMSTOR CABINET

ARMORGARD FLAMSTOR CABINET
The Armorgard cabinet is built to the same exacting specification as our popular Flamstor cabinet, but with the addition of specially designed flameproof vents to prevent build-up of fumes.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Armorgard Ltd
What makes this CABINET the right choice?
ARMORGARD FLAMSTOR CABINET
The secure storage cabinet that keeps your hazardous substances safe, organised and accessible. The Armorgard cabinet is built to the same exacting specification as our popular Flamstor cabinet, but with the addition of specially designed flameproof vents to prevent build-up of fumes. Supplied with adjustable shelves and heavy-duty 5 lever deadlocks, this robust cabinet comes complete with warning stickers and complies with all COSHH regulations, ensuring that your hazardous substances are kept safe, accessible and secure.
Specification:
- Built to specification for 1/2 hour fire resistance
- Finished in bright red with relevant hazard warning signs fitted as standard
- Keyed alike 5-lever deadlocks both sides, with heavy-duty chubb-style keys and welded security ID numbers
- Suitable for chemicals or flammables
- Fully adjustable shelves with all sizes of cabinet
- High & low level ventilation to prevent build-up of fumes
- Fork skids with fixing slots for easily adding castors
- Powder coated for maximum durability
- Flame arrester gauze fitted on all ventilation
- Fully welded and tested sump base to prevent leakage
Sizes:
- Flamstor Cabinet FSC1 - 500mm W x 530mmm D x 980mm H Weight - 45kg
- Flamstor Cabinet FSC2 - 800mm W x 585mmm D x 1250mm H Weight - 74kg
- Flamstor Cabinet FSC3 - 1205mm W x 580mmm D x 1555mm H Weight - 111kg
Technical data
Full specifications
| Physical | |
| Empty weight | 45 kg |
| Reference | |
| SKU | FSC1 |
| EDEL code | EDELP00002081 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.