ALTECNIC TEMPERATURE & PRESSURE RELIEF

ALTECNIC TEMPERATURE & PRESSURE RELIEF VALVE
TEMPERATURE AND PRESSURE RELIEF VALVE Safety valve on domestic unvented cylinders, providing relief should the domestic hot water system overheat or overpressure for any reason.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Kingspan Albion
What makes this VALVE the right choice?
TEMPERATURE AND PRESSURE RELIEF VALVE
Safety valve on domestic unvented cylinders, providing relief should the domestic hot water system overheat or overpressure for any reason. Pre-set at 90°C / 7 bar
Suitable for most unvented cylinders including Ultrasteel, Tribune HE, RM, Megaflo, ThermaQ cylinders
Specification:
- DZR Brass
- 15mm x 1/2" connections
Technical data
Full specifications
| Reference | |
| SKU | 0025490 |
| EDEL code | DELIVERY |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.
Verified customers
What buyers say
Still not sure which tank you need?
Our specialists have advised thousands of Irish customers. Free advice, no obligation.