ADBLUE BUND TANK ALARM

ADBLUE BUND TANK ALARM
AdBlue storage solution for commercial and agricultural fleets. UV-stabilised polyethylene with full chemical compatibility.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Centre Tank Services Ltd
What makes this ALARM the right choice?
ADBLUE BUND TANK ALARM
The AdBlue Bund Alarm is an economy, entry level, battery powered tank alarm system for alerting the user to fluid being detected between the inner tank and the outer bund. If only a bund alert is needed for your tank, this bund alarm is a simple, cost-effective solution and doesn't involve the other warnings associated with a tank level alarm. A red LED will flash and a 90db alarm will sound to alert the user to fluid being detected in the bund - which can be caused by a tank rupture/leak or rainwater collecting in the bund - meaning your bund will need cleaning and/or emptying.
This battery powered AdBlue bund alarm allows 72 hours of full alarm mode, making it ideal for unmanned sites and those with site closure on weekends. Further features include a weatherproof enclosure and test and alarm mute buttons to silence the sounder.
Features:
- An economical, entry level tank alarm solution c/w 5m probe for use on an AdBlue Tank
- Bund version to indicate the presence of fluid in the bund
- Battery powered for use on portable installations or site where mains power is inaccessible
- Flashing red LED & 90db alarm will sound to alert the user to a problem
- Test & alarm mute function
- Weatherproof IP55 enclosure with 4 x external mounting lugs
- Simple operation means battery will last in excess of 72 hours in full alarm mode, making it ideal for sites not always manned
- Comes with fittings to make it suitable for either plastic or steel tanks
Technical data
Full specifications
| Reference | |
| SKU | SWS3021 |
| EDEL code | EDELP00182267 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.