2 1/2" TRIPLE PUMP BOOSTER SET 150L/MI

2 1/2" TRIPLE PUMP BOOSTER SET 150L/MIN @ 4.5 BAR
Cold water booster pump set for improving mains water pressure in domestic and commercial properties.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Direct Pumps & Tanks
What makes this BAR the right choice?
2 1/2" TRIPLE PUMP BOOSTER SET 150L/MIN @ 4.5 BAR
This Triple Pump Vari-RS Booster Set is a compact water booster set ideal for residential and light commercial installations. Despite it's compact size, the Var-RS Booster Set includes advanced features normally found on larger booster sets including fault signals and an error code display as standard.
APPLICATIONS:-
- Building services
- Air conditioning
- Heating
- Water lifting and handling
- irrigation
- Washing systems
OPERATION:
The Vari-RS cold water booster set uses the RS variable speed inverter and is installed onto the Motor Connection Box of each pump in the set. The inverter regulates the rotational speed of the pump using the electrical frequency. The inverter operates at a minimal value that meets the users demand. In simple terms, once the pressure drops, the inverter recognises the drop in pressure and instructs the pumps to increase speed in order to meet the proportional demand. The RS inverter works in a “master/slave” arrangement and shares the operational duty in 60 minute cycles, this ensures joint usage across the system.
SPECIFICATION:
- 306 Stainless steel WRAS approved pumps
- BMS Volt Free Contacts
- Variable speed inverter
- Dry run protection
- PWB 8 litres WRAS approved pressure vessel
- Glycerine filled pressure gauge
- Tested and programmed prior dispatch
- Stainless steel Fittings
- Available in single and twin set options (please enquire from sales team on 051 351325)
Technical data
Full specifications
| Physical | |
| L × W × H | 61 × 90 × 92 cm |
| L × W × H (mm) | 608 × 900 × 920 |
| Reference | |
| SKU | 3RS306/8DPT |
| EDEL code | EDELP00002097 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.