2 1/2" 320L/MIN @ 5.0 BAR FLYVAR TRIPLE VARIABLE SPEED BOOSTER SET
If the supply of water fails during operation, the pumps automatically shuts down to prevent damage and re-starts again once water is restored.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Direct Pumps & Tanks
What makes this SET the right choice?
2 1/2" 320L/MIN @ 5.0 BAR FLYVAR TRIPLE VARIABLE SPEED BOOSTER SET
The Tanks.IE twin pump constant pressure cold water booster set, is designed to increase the pressure of water services within a building where the existing incoming main is not sufficient. If the supply of water fails during operation, the pumps automatically shuts down to prevent damage and re-starts again once water is restored. The pressure boosters are suitable for private water supply applications, particularly where constant pressure is required or where there are large fluctuations in demand.
Tanks.ie FlyVar SE Twin Pump Set
Designed to suit domestic and light commercial systems with hot and cold supply pipes. Ideally suited for systems with unvented cylinders and high resistance and flow bathroom fittings.
Pre-fitted pressure vessel ensures smooth running and reduces the run time of the pump for longer lifespan. Can be used for potable water applications, as WRAS approved pump and high-quality fittings.
Each pump operates within a 60-65dB noise rating at max speed, data recorded from 1 m distance to a ± 2.5dB.
Key Features
- Pre-commissioned units
- Plug and play system
- 304 Stainless steel WRAS approved pumps
- Bluetooth connection
- Variable speed inverter
- Dry run protection
- 2no PWB 12 litres WRAS approved pressure vessel
- Glycerine filled pressure gauge
- Tested and programmed prior dispatch
- Stainless-steel Fittings
- Air-cooled inverters
- Available in twin and triple set options
Technical data
Full specifications
| Physical | |
| L × W × H | 64 × 70 × 80 cm |
| L × W × H (mm) | 640 × 700 × 800 |
| Reference | |
| SKU | 3MX10-06RS/SE |
| EDEL code | EDELP00002097 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.