190L AQUA TANK PRO

190L AQUA TANK PRO
A packaged pump station is used when gravity drainage on site cannot be achieved.
Estimate delivery costs
Your Eircode lets us show an accurate delivery cost before checkout.
Direct Pumps & Tanks
What makes this PRO the right choice?
190L AQUA TANK PRO
Suitable for Removing Grey Water From: Final Effluent from Sewage Treatment Plants, Drainage of Cellars & Basements, Sinks, Showers, Kitchens & Dishwashers. A packaged pump station is used when gravity drainage on site cannot be achieved. The Aqua tank Pro is suited for clean, dirty or slightly polluted water. This unit has been designed to pump water from a septic tank or treatment plant. Our packaged pump station systems are designed to have a 24 hour storage capacity and are manufactured to BSEN752-6 standards. The system comes in four different depths, 635, 1000, 1500 and 2000mm. The units are available from stock. All you need is supplied so you just need to supply the pipework to and from the station, plus any fittings. A high water alarm is available if required.
The Aqua Pro Pumping Station comes with a submersible pump with 10mm solid handling for peace of mind.
The AquaTank and AquaTank Pro can collect grey water from showers and wash-hand basins however, they are not suitable for foul/sewage waste from toilets. If this is required, please see our Micro Series pump station range.
Pump:
- Polypropylene Plastic
- 10mm (1 ¼'') solids handling capacity
- Coolant filled motor
- Mechanical seal
- 10 Meter cable
- Max 6 Meter lift
- Max flow 5 L/sec
- Float switch as standard
Tank:
- Polyethylene tank
- 190L capacity
- Screw down lid (Pedestrian rated)
- 1 x 110mm/160mm inlet seal to allow inlet to be drilled on site
- 40mm cable duct
- 1 ¼'' internal pipe work
- 1 ¼'' non-return valve
- 1 ¼'' quick release coupling
- 1 ¼'' cable duct
Special audible/visual high level alarm control box available
Technical data
Full specifications
| Physical | |
| Capacity | 200 L |
| Reference | |
| SKU | AQUA190T |
| EDEL code | EDELP00002097 |
Irish regulations
Installation & requirements
OFTEC regulation
All domestic oil tank installations in Ireland must be carried out by an OFTEC-registered technician. The tank must conform to IS:293 and be sited in accordance with IS:820.
Site requirements
The tank must stand on a level, load-bearing concrete base minimum 100 mm thick, extending 300 mm beyond the tank footprint on all sides. Ground must be clear of vegetation.
Bunding requirements
Bunded tanks are required within 10 m of a watercourse or drain. Secondary containment must hold 110% of the inner tank capacity. Check local planning conditions before installation.
Technical documentation
Downloads & data sheets
Verified customers
What buyers say
Still not sure which tank you need?
Our specialists have advised thousands of Irish customers. Free advice, no obligation.